Suppr超能文献

用于无晶状体矫正的长戴型隐形眼镜和人工晶状体。

Extended-wear contact lenses and intraocular lenses for aphakic correction.

作者信息

Stark W J, Kracher G P, Cowan C L, Taylor H R, Hirst L W, Oyakawa R T, Maumenee A E

出版信息

Am J Ophthalmol. 1979 Sep;88(3 Pt 2):535-42. doi: 10.1016/0002-9394(79)90511-7.

Abstract

We evaluated extended-wear soft contact lens use in 128 aphakic eyes of 113 patients, 44 of whom had been unable to wear conventional contact lenses; 116 eyes (91%) have been successfully fitted and have worn the extended-wear lenses without significant complication. Eleven patients were unable to wear the lens or had to be discontinued for transient lens-related problems. In 103 eyes successfully fitted the lens is removed for cleaning less often than monthly. Ninety six of the 116 eyes fitted have visual acuity as good as, or better than, with aphakic correcting spectacles. The results obtained with the extended-wear soft contact lens are similar to those obtained with intraocular lenses, except for the recent high incidence of inflammation seen after intraocular lens insertion when using ethylene-oxide-sterilized lenses.

摘要

我们对113例患者的128只无晶状体眼使用长戴型软性接触镜进行了评估,其中44例患者此前无法佩戴传统接触镜;116只眼(91%)成功验配并佩戴长戴型镜片,未出现严重并发症。11例患者无法佩戴镜片或因短暂的镜片相关问题而不得不停戴。在103只成功验配的眼中,镜片取出清洁的频率低于每月一次。116只验配眼中有96只的视力与无晶状体矫正眼镜相当或更好。长戴型软性接触镜所获得的结果与人工晶状体相似,只是在使用环氧乙烷灭菌的人工晶状体植入后近期炎症发生率较高。

相似文献

3
Extended-wear soft contact lenses for aphakic correction.用于无晶状体眼矫正的长戴型软性隐形眼镜。
Arch Ophthalmol. 1983 Jan;101(1):39-41. doi: 10.1001/archopht.1983.01040010041003.
4
Extended-wear Hydrocurve and Sauflon contact lenses.长戴型Hydrocurve和索芙伦隐形眼镜。
Am J Ophthalmol. 1980 Sep;90(3):309-16. doi: 10.1016/s0002-9394(14)74909-8.
5
Extended-wear contact lenses in 525 aphakic eyes.525只无晶状体眼中的长戴型隐形眼镜。
Am J Ophthalmol. 1979 Sep;88(3 Pt 1):351-3. doi: 10.1016/0002-9394(79)90632-9.
6
Extended wear contact lenses for aphakia.
Am J Optom Physiol Opt. 1981 Jun;58(6):467-71. doi: 10.1097/00006324-198106000-00006.
8
Intracorneal hemorrhage secondary to aphakic contact lens wear.
Cornea. 1992 Jan;11(1):73-6. doi: 10.1097/00003226-199201000-00011.
10
Pediatric aphakic contact lens wear: rates of successful wear.小儿无晶状体隐形眼镜佩戴:成功佩戴率
J Pediatr Ophthalmol Strabismus. 1993 Jul-Aug;30(4):253-8. doi: 10.3928/0191-3913-19930701-08.

引用本文的文献

1
Disease and risks associated with contact lenses.与隐形眼镜相关的疾病及风险。
Br J Ophthalmol. 1993 Jan;77(1):49-53. doi: 10.1136/bjo.77.1.49.
3
Intraocular lenses.人工晶状体
J R Soc Med. 1983 Mar;76(3):169-72. doi: 10.1177/014107688307600301.
5
Contact lenses for infant aphakia.用于婴儿无晶状体眼的隐形眼镜。
Br J Ophthalmol. 1990 Mar;74(3):150-4. doi: 10.1136/bjo.74.3.150.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验