Suppr超能文献

喉传入纤维对机械和化学刺激的反应。

The response of laryngeal afferent fibres to mechanical and chemical stimuli.

作者信息

Boushey H A, Richardson P S, Widdicombe J G, Wise J C

出版信息

J Physiol. 1974 Jul;240(1):153-75. doi: 10.1113/jphysiol.1974.sp010605.

Abstract
  1. We have recorded afferent activity from ;single fibres' dissected from the superior laryngeal nerve of anaesthetized cats.2. Units which responded to gentle mechanical stimulation of the larynx epithelium were chosen for study.3. Receptors with myelinated fibres were grouped according to their spontaneous activity. Group 1 fibres had little or no spontaneous activity: group 2 fibres had constant and continuous spontaneous activity.4. Group 1 fibres had a wide range of adaptation rates. Their conduction velocities lay between 3.0 and 30 m/sec. The receptors were generally stimulated by ammonia and distilled water and often by CS riot control agent, 5 and 10% CO(2), 200 ppm SO(2), and cigarette smoke. Histamine, phenyl diguanide, graphite dust, 100 ppm SO(2) and saline drops did not generally excite the fibres.5. Group 2 fibres were slowly adapting. Their conduction velocities ranged between 8.0 and 26.5 m/sec. Ammonia usually, and distilled water sometimes, excited these fibres while 5 and 10% CO(2) mixtures inhibited them. A minority of group 2 fibres were pH sensitive, inhibited by acids and stimulated by alkaline buffers. Cigarette smoke had complex actions, either excitation, inhibition or, at different times, both. Histamine, P.d.g., CS, SO(2), saline drops and dust had no action on these fibres.6. Recordings were made from one unmyelinated fibre (conduction velocity 1.9 m/sec) which responded to stroking of the epithelium with a thread and to histamine, P.d.g. and ammonia vapour applied to the epithelium.7. We consider the site, method of excitation and reflex actions of the different receptors described.
摘要
  1. 我们记录了从麻醉猫的喉上神经分离出的“单纤维”的传入活动。

  2. 选择对喉部上皮进行轻柔机械刺激有反应的单位进行研究。

  3. 有髓纤维的感受器根据其自发活动进行分组。第1组纤维几乎没有或没有自发活动;第2组纤维有持续不断的自发活动。

  4. 第1组纤维有广泛的适应率。它们的传导速度在3.0至30米/秒之间。感受器通常受到氨和蒸馏水的刺激,也常常受到防暴催泪剂、5%和10%的二氧化碳、200 ppm的二氧化硫以及香烟烟雾的刺激。组胺、苯基双胍、石墨粉尘、100 ppm的二氧化硫和盐水滴通常不会刺激这些纤维。

  5. 第2组纤维适应缓慢。它们的传导速度在8.0至26.5米/秒之间。氨通常能刺激这些纤维,蒸馏水有时也能刺激,而5%和10%的二氧化碳混合物则会抑制它们。少数第2组纤维对pH敏感,受酸抑制,受碱性缓冲液刺激。香烟烟雾有复杂的作用,要么兴奋,要么抑制,或者在不同时间两者兼有。组胺、苯基双胍、催泪剂、二氧化硫、盐水滴和粉尘对这些纤维没有作用。

  6. 对一根无髓纤维(传导速度1.9米/秒)进行了记录,该纤维对用线轻拂上皮以及向上皮施加组胺、苯基双胍和氨蒸气有反应。

  7. 我们考虑了所描述的不同感受器的部位、兴奋方法和反射作用。

相似文献

引用本文的文献

2
Sensory Innervation of the Larynx and the Search for Mucosal Mechanoreceptors.喉的感觉神经支配与黏膜机械感受器的探寻
J Speech Lang Hear Res. 2021 Feb 17;64(2):371-391. doi: 10.1044/2020_JSLHR-20-00350. Epub 2021 Jan 19.
5
9
Otolaryngology head and neck surgery: an integrative view of the larynx.耳鼻喉科学头颈外科学:喉的综合视图。
Head Neck. 2011 Oct;33 Suppl 1(0 1):S46-53. doi: 10.1002/hed.21901. Epub 2011 Sep 9.
10
Cortical gating of oropharyngeal sensory stimuli.口咽感觉刺激的皮质门控。
Front Physiol. 2010 Jan 25;1:167. doi: 10.3389/fphys.2010.00167. eCollection 2010.

本文引用的文献

3
AFFERENT DISCHARGES FROM LARYNGEAL ARTICULAR MECHANORECEPTORS.
Nature. 1965 Jan 2;205:86-7. doi: 10.1038/205086a0.
7
Afferent impulses in the recurrent laryngeal nerve in the cat.
Laryngoscope. 1961 Oct;71:1196-206. doi: 10.1288/00005537-196110000-00007.
9
Effects of cold air on respiratory airflow resistance in patients with respiratory-tract disease.
N Engl J Med. 1960 Aug 11;263:268-73. doi: 10.1056/NEJM196008112630602.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验