The use of human serum albumin labelled with iodine-131 (RIHSA) as the radioactive indicator in the measurement of cardiac output by the external counting technique is not ideal since the emission characteristics, physical half-life, and physiological fate restrict the amount that can be administered. A more suitable material, especially because of the short physical half-life of the isotope involved, is albumin labelled with technetium-99m. This communication describes a simple three-stage process for the preparation of such a complex which was then tested in subjects with no impairment of cardiac performance for its suitability in assays of cardiac output by the external counting method. Values were within the same range as those obtained with RIHSA in comparable subjects. Blood volumes estimated with Tc-albumin were within the limits of physiological variation of values derived with RIHSA in the same subjects. Serial blood samplings and urine collection during a period of 24 hours after administration showed that the preparation was lost continuously from the circulation at a more rapid rate than RIHSA. The greatest loss was in the first few hours when most of the urinary excretion of the isotope occurred. Comparison of the present data with published results using an alternative preparation suggests that our product may be more stable.

摘要

将用碘 - 131标记的人血清白蛋白(RIHSA)作为放射性指示剂,通过外部计数技术测量心输出量并不理想,因为其发射特性、物理半衰期和生理转归限制了可给予的量。一种更合适的物质,特别是考虑到所涉及同位素的物理半衰期较短,是用锝 - 99m标记的白蛋白。本通讯描述了制备这种复合物的简单三阶段过程,然后在心脏功能无损害的受试者中测试其通过外部计数法测定心输出量的适用性。所得值与在可比受试者中用RIHSA获得的值在同一范围内。用锝 - 白蛋白估计的血容量在同一受试者中用RIHSA得出的值的生理变化范围内。给药后24小时内的连续血样采集和尿液收集表明,该制剂从循环中持续丢失的速度比RIHSA更快。最大的丢失发生在最初几个小时,此时同位素的大部分经尿液排泄。将目前的数据与使用另一种制剂的已发表结果进行比较表明,我们的产品可能更稳定。

相似文献

6
Clinical control in shock.休克的临床控制
J Clin Pathol Suppl (R Coll Pathol). 1970;4:32-6. doi: 10.1136/jcp.s3-4.1.32.

本文引用的文献

1
PREPARATION OF TECHNETIUM (TC99M)-LABELED SERUM ALBUMIN (HUMAN).锝(Tc99m)标记的人血清白蛋白的制备
Int J Appl Radiat Isot. 1965 Apr;16:283-8. doi: 10.1016/0020-708x(65)90182-1.
9
Placental localization using 99m technetium-labelled serum albumin.使用99m锝标记血清白蛋白进行胎盘定位。
J Obstet Gynaecol Br Commonw. 1968 Apr;75(4):470-3. doi: 10.1111/j.1471-0528.1968.tb00146.x.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验