Brachman M, Tanasescu D, Ramanna L, Berman D, Waxman A
Clin Nucl Med. 1979 Oct;4(10):415-6. doi: 10.1097/00003072-197910000-00005.
A case of a ventilation-perfusion mismatch seen post-operatively in a patient with chest pain is reported. There was absence of perfusion to the right lung, with relatively normal ventilation. The study was initially interpreted as indicating a high probability of pulmonary embolus. It was then discovered that the injection had been inadvertently made into a Swan-Ganz catheter, with its tip in the left main pulmonary artery. The mismatch was therefore iatrogenic and not related to pulmonary embolus. The false-positive lung imaging which resulted has not been previously reported in the literature.
报告了1例术后胸痛患者出现通气-灌注不匹配的病例。右肺无灌注,通气相对正常。该研究最初被解释为提示肺栓塞的可能性很大。随后发现注射无意中注入了一根尖端位于左主肺动脉的 Swan-Ganz 导管。因此,这种不匹配是医源性的,与肺栓塞无关。由此导致的假阳性肺显像此前在文献中尚未见报道。