Magrini A, Gigante G E, Salmi M, Giacomello A
Eur J Nucl Med. 1979 Aug 1;4(4):291-4. doi: 10.1007/BF00304887.
An X-ray fluorescence technique was employed to study the clearance rate from the knee joint of an intraarticularly injected stable tracer. Clearance curves, determined in two normal volunteers and in three patients with various articular diseases, were found to be of the monoexponential type in agreement with results obtained by authors employing radioactive tracers. Clearance half-time values in basal conditions were higher in the normal knee joint than in the inflamed knee joint. The effect of a corticosteroid suspension injected into the knee joint was also studied. Preliminary results obtained indicate that the X-ray fluorescence technique can be employed, with some advantages compared with the radiotracer technique, for quantitative determination of spontaneous or pharmacologically induced changes in joint inflammation.
采用X射线荧光技术研究关节内注射稳定示踪剂后从膝关节的清除率。在两名正常志愿者和三名患有各种关节疾病的患者中测定的清除曲线为单指数类型,这与使用放射性示踪剂的作者所获得的结果一致。基础条件下正常膝关节的清除半衰期值高于发炎膝关节。还研究了注入膝关节的皮质类固醇混悬液的作用。获得的初步结果表明,与放射性示踪剂技术相比,X射线荧光技术具有一些优势,可用于定量测定关节炎症的自发或药物诱导变化。