生理有害化学物质对防护手套材料的渗透

Permeation of glove materials by physiologically harmful chemicals.

作者信息

Williams J R

出版信息

Am Ind Hyg Assoc J. 1979 Oct;40(10):877-82. doi: 10.1080/15298667991430433.

Abstract

The breakthrough times and permeation rates of 1,4-dichloro-2-butene, benzene, carbon tetrachloride, and 2-chloro-1,3-butadiene for eleven commercially available gloves were determined. Four methods of determining the breakthough time and permeation rate were evaluated. A wide variation in the glove material thickness and protection time was found showing that the adequate protection time can only be determined by testing the proposed glove with the chemicals to be handled.

摘要

测定了1,4-二氯-2-丁烯、苯、四氯化碳和2-氯-1,3-丁二烯在11种市售手套中的突破时间和渗透速率。评估了四种测定突破时间和渗透速率的方法。结果发现手套材料厚度和防护时间差异很大,这表明只有通过用待处理化学品对手套进行测试,才能确定足够的防护时间。