A high-performance liquid chromatographic method is described for the simultaneous determination of methylprednisolone (MP) and methylprednisolone hemisuccinate (MPHS), or hydrocortisone (HC) and hydrocortisone hemisuccinate (HCHS) in human serum. Reversed-phase liquid chromatography was performed on a microparticulate C18 column (Spherisorb, 5 micron) using a mobile phase of 2% glacial acetic acid, 30--35% acetonitrile, 70--65% water with ultraviolet detection (254 nm). The method uses 17 alpha-hydroxyprogesterone as the internal standard for the determination of methylprednisolone and its hemisuccinate ester, or 11-deoxy-17-hydroxycorticosterone as the internal standard for the determination of hydrocortisone and its hemisuccinate ester. The sensitivity is 0.03 microgram/ml for HC, 0.07 microgram/ml for MP, 0.04 microgram/ml for MPHS, and 0.10 microgram/ml for HCHS, with a detection limit of 0.02 microgram/ml for all four steroids. Calibration curves are linear up to 3 micrograms/ml for MP or MPHS (as equivalent MP) and up to 4 micrograms/ml for HC and 7 micrograms/ml (as equivalent HC) for HCHS. The pooled relative standard deviation for replicate for each steroid is less than 7%. Plasma concentration--time curves are reported for MP and MPHS or HC and HCHS of two human subjects following intramuscular administration of 125 mg of methylprednisolone sodium succinate for injection, U.S.P., or 250 mg of hydrocortisone sodium succinate for injection, U.S.P.

摘要

本文描述了一种高效液相色谱法,用于同时测定人血清中的甲泼尼龙(MP)和甲泼尼龙半琥珀酸酯(MPHS),或氢化可的松(HC)和氢化可的松半琥珀酸酯(HCHS)。采用反相液相色谱法,在微粒C18柱(Spherisorb,5微米)上进行分析,流动相为2%冰醋酸、30 - 35%乙腈、70 - 65%水,采用紫外检测(254纳米)。该方法使用17α-羟孕酮作为测定甲泼尼龙及其半琥珀酸酯的内标,或11-脱氧-17-羟皮质酮作为测定氢化可的松及其半琥珀酸酯的内标。HC的灵敏度为0.03微克/毫升,MP为0.07微克/毫升,MPHS为0.04微克/毫升,HCHS为0.10微克/毫升,四种甾体的检测限均为0.02微克/毫升。MP或MPHS(以等效MP计)的校准曲线在3微克/毫升以内呈线性,HC在4微克/毫升以内呈线性,HCHS在7微克/毫升(以等效HC计)以内呈线性。每种甾体重复测定的合并相对标准偏差小于7%。报告了两名受试者肌肉注射125毫克美国药典注射用甲泼尼龙琥珀酸钠或250毫克美国药典注射用氢化可的松琥珀酸钠后MP和MPHS或HC和HCHS的血浆浓度-时间曲线。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验