Nair R, Wrede D E, Kartha M, Batley F
Rev Interam Radiol. 1979 Oct;4(4):169-72.
There are several different methods in vogue at present in determining patient midplane doses in the "mantle" treatment for Hodgkin's disease and malignant lymphomas. A method of determining midplane doses in individual cases using thermoluminescent dosimetry is presented. It shows excellent agreement with the midplane doses measured in an Alderson-Rando phantom treated as a hypothetical "mantle" patient.