Bertina R M, van der Linden I K
Clin Chim Acta. 1977 Jun 15;77(3):275-86. doi: 10.1016/0009-8981(77)90230-3.
A rabbit antibody specifically precipitating human factor IX has been used in the assay of factor IX antigen. The results obtained with two different methods (inhibitor-neutralisation assay and electro-immunoassay) have been compared in a group of healthy individuals and in a group of hemophilia B patients and carriers. In general, identical results are obtained with both methods, except in some hemophilia B+ carriers and patients, where the electroimmuno assay gives 1.5-2.0 times higher levels. Results obtained by electroimmuno assay are more accurate and reproducible than those obtained by inhibitor-neutralisation assay, which is of importance for its potential use in carrier detection.
一种能特异性沉淀人凝血因子IX的兔抗体已用于凝血因子IX抗原的检测。在一组健康个体以及一组B型血友病患者和携带者中,对两种不同方法(抑制剂中和测定法和电免疫测定法)所获得的结果进行了比较。总体而言,两种方法得到的结果相同,但在一些B型血友病携带者和患者中除外,电免疫测定法测得的水平要高出1.5至2.0倍。与抑制剂中和测定法相比,电免疫测定法所获得的结果更准确且可重复,这对于其在携带者检测中的潜在应用具有重要意义。