Alterations in blood pressure during exchange transfusion.

作者信息

Aranda J V, Sweet A Y

出版信息

Arch Dis Child. 1977 Jul;52(7):545-8. doi: 10.1136/adc.52.7.545.

Abstract

Blood pressure changes as a function of the rates of blood withdrawal and infusion were determined during exchange blood transfusion in 2 preterm newborn infants. 10 ml blood withdrawal and infusion completed within 3 minutes resulted in reversible changes in aortic pressure, whereas the same procedure completed within 45 to 60 seconds resulted in a progressive fall in the systolic pressure and in narrowing of the pulse pressure. In one of the cases this was associated with respiratory arrest. An exchange rate of 5 ml/kg per 3 minutes is recommended.

摘要

在2例早产新生儿换血输血过程中,测定了血压随抽血和输血速度的变化情况。在3分钟内完成10毫升的抽血和输血会导致主动脉压力出现可逆性变化,而在45至60秒内完成相同操作则会导致收缩压逐渐下降和脉压变窄。在其中1例病例中,这与呼吸骤停有关。建议每3分钟的换血速度为5毫升/千克。