Wright J S, Newman D C, Stacey R B
Med J Aust. 1977 Jun 4;1(23):839-40. doi: 10.5694/j.1326-5377.1977.tb131168.x.
Glutaraldehyde preservation of heterograft valves has increased their durability. Sixty-nine Hancock prostheses have been implanted, 30 in the mitral position and 39 in the aortic position. Anticoagulants have not been administered. There has been one important thromboembolic complication and periprosthetic mitral incompetence has occurred in three instances, but prosthetic incompetence has not developed. Two asymptomatic aortic diastolic murmurs have been noted. After a follow-up ranging between two and 19 months, it appears that the Hancock prosthesis offers a valuable alternative to mechanical valve replacement and anticoagulants are not required as a routine.
戊二醛保存的异种移植瓣膜提高了其耐用性。已植入69个汉考克假体,其中30个植入二尖瓣位置,39个植入主动脉位置。未使用抗凝剂。发生了1例重要的血栓栓塞并发症,3例出现人工瓣膜周围二尖瓣关闭不全,但未出现人工瓣膜功能不全。发现2例无症状的主动脉舒张期杂音。经过2至19个月的随访,看来汉考克假体为机械瓣膜置换提供了一种有价值的替代方案,并且无需常规使用抗凝剂。