Suppr超能文献

[用弹性体硅酮假体替代犬肝外胆总管。其在胆道手术中的可能应用]

[Replacement of the extra-hepatic common bile duct in the dog by an elastomere silicone prosthesis. Its possible application in biliary surgery].

作者信息

Kron B

出版信息

J Chir (Paris). 1977;114(4):237-56.

PMID:591589
Abstract

From an experimental study of the prosthetic replacement of the common bile duct in the dog by an silicone elestomere prothesis, according to the technic of double intubation with a 2 1/2 year follow up in the oldest cases, and complete reconstitution of a well-structured new bile duct, the author propose using a similar prosthesis in biliary surgery: --firstly, the carcinoma of the bile ducts, using an internal prosthesis hepatico-gastric, hepatico-jejunal or duodenal, which is eliminated internally; --secondly, in stenosis or operative wounds of the bile ducts, using either removable tutor prosthesis, or segmental prostheses lost internally.

摘要

通过对狗的胆总管进行硅胶弹性体假体置换的实验研究,按照双插管技术并对最老的病例进行了2年半的随访,以及对结构良好的新胆管进行完全重建,作者提议在胆道手术中使用类似的假体:——首先,对于胆管癌,使用肝胃、肝空肠或十二指肠内假体,该假体可在内部消除;——其次,对于胆管狭窄或手术伤口,使用可移除的支撑假体或在内部丢失的节段性假体。