Suppr超能文献

使用艾本德火焰光度计自动估算尿钙含量。

Automated estimation of urinary calcium using the Eppendorf flame photometer.

作者信息

Bold A M

出版信息

J Clin Pathol. 1966 Nov;19(6):625-8. doi: 10.1136/jcp.19.6.625.

Abstract

A method is described for estimating urine calcium on a mechanized Eppendorf flame photometer with twin channels at a rate of 60 per hour. Sodium is estimated simultaneously so that a correction can be made for the small sodium error. Errors due to potassium and phosphate are minimized by adding these ions to the standards and to the diluting fluid. Results agree well with those obtained by Trinder's naphthal-hydroxamic acid precipitation method.

摘要

本文描述了一种在具有双通道的机械化艾本德火焰光度计上以每小时60个样本的速率估算尿钙的方法。同时估算钠含量,以便对小的钠误差进行校正。通过将钾离子和磷酸根离子添加到标准液和稀释液中,可将由它们引起的误差降至最低。结果与通过Trinder的萘异羟肟酸沉淀法获得的结果非常吻合。