Sullivan J F, Songer J R, Mathis R G
Appl Microbiol. 1967 Jan;15(1):191-6. doi: 10.1128/am.15.1.191-196.1967.
The procedures and equipment needed to measure filtration efficiency by means of fluorescent aerosols are described. The filtration efficiency of individual lots of spun-glass air filtration medium or of entire air filtration systems employing such media was determined. Data relating to the comparative evaluation of spun-glass filter media by means of the fluorometric method described, as well as by conventional biological procedures, are presented.
描述了通过荧光气溶胶测量过滤效率所需的程序和设备。测定了各批玻璃棉空气过滤介质或使用此类介质的整个空气过滤系统的过滤效率。还给出了通过所述荧光法以及传统生物学程序对玻璃棉过滤介质进行比较评估的数据。