Suppr超能文献

使用分散的豚鼠肾上腺细胞对未提取的人血浆中的促肾上腺皮质激素(ACTH)进行生物测定的初步经验。

Preliminary experiences with a bioassay for adrenocorticotrophin (ACTH) in unextracted human plasma using dispersed guinea-pig adrenal cells.

作者信息

Lambert A, Frost J, Robertson W R

出版信息

Clin Endocrinol (Oxf). 1984 Jul;21(1):33-41. doi: 10.1111/j.1365-2265.1984.tb00133.x.

Abstract

A simple, accurate and precise dispersed cell bioassay suitable for the assay of ACTH levels greater than 50 ng/1 in unextracted human plasma is described. Isolated adrenal cells were prepared by tryptic digestion of the guinea-pig adrenal gland and cortisol production by these cells was controlled specifically by ACTH. The cortisol response to 2 ng/1 of human pituitary ACTH (1-39) was always significantly (P less than 0.05, n = 17) different from the control. ACTH concentrations between 1 and 20 ng/1 gave a 14 +/- 3 fold (n = 17) increment in cortisol response. Dilutions of test plasmas were parallel with standard ACTH (1-39) when the plasma concentrations were maintained throughout at 4% (1 in 25 dilution) by the addition of dexamethasone-suppressed plasma ('ACTH free'). Using a 25 fold plasma dilution, the limit of detection of ACTH in unextracted plasma was 50 ng/1. Recovery of ACTH (1-39) spiked into dexamethasone suppressed plasma at concentrations of 250 and 100 ng/1 was 97 +/- 10% (n = 17) and 114 +/- 15% (n = 17) respectively. The within assay coefficient of variation (CV) of both quality control and patients' samples never exceeded 9% while between assay variation was less than or equal to 13%. The sample throughput was 30 plasma samples/week/technician.

摘要

本文描述了一种简单、准确且精密的分散细胞生物测定法,适用于测定未提取的人血浆中高于50 ng/1的促肾上腺皮质激素(ACTH)水平。通过胰蛋白酶消化豚鼠肾上腺制备分离的肾上腺细胞,这些细胞的皮质醇生成由ACTH特异性控制。对2 ng/1人垂体ACTH(1-39)的皮质醇反应与对照相比总是有显著差异(P<0.05,n = 17)。1至20 ng/1的ACTH浓度使皮质醇反应增加了14±3倍(n = 17)。当通过添加地塞米松抑制的血浆(“无ACTH”)使血浆浓度始终保持在4%(25倍稀释)时,测试血浆的稀释液与标准ACTH(1-39)呈平行关系。使用25倍血浆稀释时,未提取血浆中ACTH的检测限为50 ng/1。以250和100 ng/1的浓度加入地塞米松抑制血浆中的ACTH(1-39)回收率分别为97±10%(n = 17)和114±15%(n = 17)。质量控制样本和患者样本的批内变异系数(CV)从未超过9%,而批间变异小于或等于13%。样本处理量为30个血浆样本/周/技术人员。

相似文献

5
A sensitive bioassay for the determination of human plasma ACTH levels.
J Clin Endocrinol Metab. 1975 Feb;40(2):268-7. doi: 10.1210/jcem-40-2-268.
9
Radioimmunoassay of ACTH in plasma.血浆促肾上腺皮质激素的放射免疫测定
J Clin Invest. 1968 Dec;47(12):2725-51. doi: 10.1172/JCI105955.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验