• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Pacemaker dependence in transient high-grade atrioventricular block.

作者信息

Rosenqvist M, Edhag K O

出版信息

Pacing Clin Electrophysiol. 1984 Jan;7(1):63-70. doi: 10.1111/j.1540-8159.1984.tb04861.x.

DOI:10.1111/j.1540-8159.1984.tb04861.x
PMID:6199772
Abstract

In a prospective study 16 patients who had been given a pacemaker because of symptomatic high-grade atrioventricular block and whose conduction had been recovered were checked for their dependence on the pacemaker. During a follow-up time ranging from 32 to 158 months (median 62 months) six patients proved to be dependent on the device owing to the development of recurrent stable high-grade atrioventricular block. The subsequent return of atrioventricular block was evidently not associated with etiology, age, sex, ECG-pattern or length of follow-up period. Five additional patients equipped with a bradycardia-indicating pacemaker all proved to be pacemaker-dependent after a follow-up time ranging from 1-20 months (median 7 months), even though atrioventricular conduction had recovered and its presence had been confirmed at regular outpatient checks. It is thus evident that the conventional clinical methods are of limited value for examining the course of conduction defect and assessing the prognosis for patients whose spontaneous cardiac activity has returned after periods of symptomatic high-grade atrioventricular block. When a bradycardia-indicating pacemaker was furnished, pacemaker dependence was demonstrated in most of the patients whose atrioventricular conduction had recovered. This confirms that pacing introduced because of symptomatic high-grade atrioventricular block should not be discontinued even if a conducted heart rhythm has been established and maintained for long periods.

摘要

相似文献

1
Pacemaker dependence in transient high-grade atrioventricular block.
Pacing Clin Electrophysiol. 1984 Jan;7(1):63-70. doi: 10.1111/j.1540-8159.1984.tb04861.x.
2
Electrocardiographic observations in bradycardia and tachycardia-dependent atrioventricular block. Relationship to supernormal phase of intraventricular conduction.
Chest. 1975 Apr;67(4):450-7. doi: 10.1378/chest.67.4.450.
3
Pacing therapy in the elderly.老年人的起搏治疗
Am J Geriatr Cardiol. 2002 Sep-Oct;11(5):305-16. doi: 10.1111/j.1076-7460.2002.00052.x.
4
Atrioventricular conduction in patients with clinical indications for transvenous cardiac pacing.有经静脉心脏起搏临床指征患者的房室传导
Br Heart J. 1975 Jun;37(6):583-92. doi: 10.1136/hrt.37.6.583.
5
Recovery of atrioventricular conduction in patients with heart block after transcatheter aortic valve replacement.经导管主动脉瓣置换术后心脏传导阻滞患者房室传导的恢复情况
J Cardiovasc Electrophysiol. 2017 Oct;28(10):1196-1202. doi: 10.1111/jce.13291. Epub 2017 Aug 4.
6
Time relation between a syncopal event and documentation of atrioventricular block in patients with bifascicular block: clinical implications.双分支阻滞患者晕厥事件与房室传导阻滞记录之间的时间关系:临床意义
Cardiology. 2007;108(2):138-43. doi: 10.1159/000096038. Epub 2006 Oct 6.
7
Atrioventricular conduction after alcohol septal ablation for obstructive hypertrophic cardiomyopathy.酒精室间隔消融术后的房室传导阻滞:梗阻性肥厚型心肌病。
J Cardiovasc Med (Hagerstown). 2014 Mar;15(3):214-21. doi: 10.2459/JCM.0b013e3283638073.
8
Late recovery of surgically-induced atrioventricular block in patients with congenital heart disease.先天性心脏病患者手术诱发房室传导阻滞的延迟恢复
J Interv Card Electrophysiol. 2002 Jun;6(2):191-5. doi: 10.1023/a:1015379903936.
9
The natural history of trifascicular disease following permanent pacemaker implantation. Significance of continuing changes in atrioventricular conduction.永久起搏器植入术后三分支疾病的自然病程。房室传导持续变化的意义。
Circulation. 1976 Nov;54(5):780-3. doi: 10.1161/01.cir.54.5.780.
10
His bundle recordings in bradycardia-dependent AV block induced by premature beats.早搏诱发的心动过缓依赖性房室传导阻滞中的希氏束记录。
Br Heart J. 1975 Jun;37(6):570-5. doi: 10.1136/hrt.37.6.570.

引用本文的文献

1
Stability of intrinsic rhythm in pacemaker-dependent patients during pacemaker replacement: Can we predict the need for temporary pacing?起搏器依赖患者在更换起搏器期间固有节律的稳定性:我们能否预测临时起搏的需求?
J Arrhythm. 2018 May 28;34(4):450-454. doi: 10.1002/joa3.12072. eCollection 2018 Aug.