Abstract

Four cases of torsion of the fallopian tube following sterilization are reported. This is a rare complication that may occur two to eight years after tubal ligation. It is more likely to occur after Pomeroy's, Irving's or the Viennese school technique of sterilization, in which the free distal segment of the fallopian tube is suspended by a narrow mesentery. Hydrosalpinx, which is common after sterilization, seems to predispose to torsion.

摘要

本文报告了4例绝育术后输卵管扭转的病例。这是一种罕见的并发症,可能在输卵管结扎术后2至8年发生。在波默罗伊氏法、欧文氏法或维也纳学派绝育技术后更易发生,这些方法中输卵管游离远端段由狭窄系膜悬吊。绝育术后常见的输卵管积水似乎易引发扭转。