A method for the sterilizing filtration of Renacidin, a urologic irrigating solution, was evaluated. Renacidin irrigation was prepared and sterilized by microporous membrane filtration. A sterilizing membrane filtration apparatus was challenged by inoculating a batch of irrigation solution with Escherichia coli. The sterility of both intentionally contaminated and routinely prepared batches was evaluated. The stability of the solution was monitored by pH measurement, visual examination, maintenance of a vacuum, and absorbance spectrum of a 1:100 dilution in deionized water over a wavelength range from 400 to 200 nm. The time required to prepare three one-liter units was about two hours. No microbial growth was detected in any of the samples. The predicted minimum shelf-life at 10 degrees C was six months. Because the prepared solution contains some unreacted citric acid and bicarbonates, storage at room temperature could produce excessive pressure inside the container from carbon dioxide gas evolution. Refrigerated storage is recommended. This method for the preparation and sterilization of Renacidin irrigation is reasonably expedient, economical, and reliable.
对一种泌尿科冲洗液——雷尼替丁的除菌过滤方法进行了评估。雷尼替丁冲洗液通过微孔膜过滤制备并灭菌。通过向一批冲洗液中接种大肠杆菌来对除菌膜过滤装置进行挑战测试。对故意污染的批次和常规制备的批次的无菌性均进行了评估。通过测量pH值、目视检查、保持真空以及在400至200nm波长范围内对去离子水1:100稀释液的吸收光谱来监测溶液的稳定性。制备三个一升单位所需的时间约为两小时。在任何样品中均未检测到微生物生长。预计在10摄氏度下的最短保质期为六个月。由于制备的溶液含有一些未反应的柠檬酸和碳酸氢盐,室温储存可能会因二氧化碳气体逸出而在容器内产生过大压力。建议冷藏储存。这种雷尼替丁冲洗液的制备和灭菌方法相当便捷、经济且可靠。