Julian T B, Ravitch M M
Surg Clin North Am. 1984 Jun;64(3):567-77. doi: 10.1016/s0039-6109(16)43339-6.
An experimental study involving circular stapled anastomoses across linear stapled closures is presented. Although the staples were deformed, cut in two, and sometimes uninjured, no complications were found. These data support the use of this technique, which is currently employed in clinic practice.