Suppr超能文献

[阴囊超声检查的陷阱]

[Pitfalls in scrotal echotomography].

作者信息

Martin-Lalardrie B, Marsot-Dupuch K

出版信息

J Radiol. 1984 Apr;65(4):251-7.

PMID:6384498
Abstract

We reviewed 500 scrotal sonograms with a gray-scale equipment using a 7 Mega Hertz transducer. 7 cases are presented in which there are the two principal traps which must be avoided in the practice of scrotal ultrasound: To find as pathological, some scrotal or parascrotal structures which are anatomical. To confuse pathological images. These diagnostic problems are almost resolved by three conditions: A perfect knowledge of normal ultrasound anatomy, a good experience of the operator in this scope and a strict management of the ultrasonic investigation. There, the scrotal sonogram is highly reliable.

摘要

我们使用一台7兆赫兹的换能器,通过灰阶设备对500份阴囊超声图像进行了回顾性研究。本文呈现了7个病例,其中存在阴囊超声检查实践中必须避免的两个主要陷阱:将一些正常的阴囊或阴囊旁结构误诊为病理性结构;混淆病理性图像。通过三个条件几乎可以解决这些诊断问题:对正常超声解剖结构的充分了解、操作者在该领域的丰富经验以及对超声检查的严格管理。在此情况下,阴囊超声检查具有高度可靠性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验