Suppr超能文献

碘曲仑,一种新型脊髓造影剂:2. 频谱分析对比脑电图评估

Iotrol, a new myelographic agent: 2. Comparative electroencephalographic evaluation by spectrum analysis.

作者信息

Sovak M, Ranganathan R, Kerber C W, Bickford R, Alksne J F

出版信息

AJNR Am J Neuroradiol. 1983 May-Jun;4(3):319-22.

Abstract

Iotrol, a nonionic dimer isotonic with cerebrospinal fluid at 300 mg l/ml, was evaluated against metrizamide, iopamidol, and iohexol by electroencephalography (EEG) in nonanesthetized cynomolgus monkeys. Each of four monkeys was injected intrathecally with 0.5 ml/kg of 300 mg l/ml of each contrast medium. EEG was obtained before, 45 min, and 3 hr postinjection. EEG spikes, motor disturbances, convulsions, and behavior changes were observed. The EEG from C3 channel was also computer-analyzed. Average percentage differences between control and test energy content of the entire EEG and of the EEG spectrum subdivided into five frequency bands were calculated. With metrizamide, three animals suffered seizures, and all were lethargic and irritable. With iopamidol, two animals convulsed; all animals were lethargic. Transient apathy and motor disturbances were observed in the iohexol animals. No motor or behavior changes were produced by iotrol. Metrizamide and iopamidol increased the spectrum energy in all bands. Neither iohexol nor iotrol affected the EEG significantly. On the basis of these findings, iotrol holds promise as a clinical contrast material for the subarachnoid space.

摘要

碘曲仑是一种在300mg/ml时与脑脊液等渗的非离子二聚体,通过脑电图(EEG)在未麻醉的食蟹猴中与甲泛葡胺、碘帕醇和碘海醇进行了对比评估。4只猴子中的每只都鞘内注射了每千克0.5ml的300mg/ml的每种造影剂。在注射前、注射后45分钟和3小时获取脑电图。观察脑电图尖峰、运动障碍、惊厥和行为变化。还对来自C3通道的脑电图进行了计算机分析。计算了整个脑电图以及细分为五个频段的脑电图频谱的对照和测试能量含量之间的平均百分比差异。使用甲泛葡胺时,3只动物发生惊厥,所有动物都无精打采且易怒。使用碘帕醇时,2只动物发生惊厥;所有动物都无精打采。在碘海醇组动物中观察到短暂的冷漠和运动障碍。碘曲仑未引起运动或行为变化。甲泛葡胺和碘帕醇增加了所有频段的频谱能量。碘海醇和碘曲仑均未对脑电图产生显著影响。基于这些发现,碘曲仑有望成为蛛网膜下腔的临床造影剂。

相似文献

5
Iohexol vs. iopamidol for myelography.
Invest Radiol. 1985 Jan-Feb;20(1 Suppl):S37-43. doi: 10.1097/00004424-198501002-00010.
6
Iotrol versus metrizamide in lumbar myelography: a double-blind study.
Radiology. 1986 Mar;158(3):845-7. doi: 10.1148/radiology.158.3.3945762.
7
Comparison of iohexol with metrizamide in myelography.
Radiology. 1984 Apr;151(1):121-2. doi: 10.1148/radiology.151.1.6701301.
10
Iohexol and metrizamide in lumbar myelography. Comparison of side effects.
Acta Radiol Diagn (Stockh). 1985 Nov-Dec;26(6):761-5. doi: 10.1177/028418518502600623.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验