Nishijima M K, Takezawa J, Taenaka N, Shimada Y, Yoshiya I
Thromb Res. 1983 Jul 15;31(2):279-84. doi: 10.1016/0049-3848(83)90330-4.
The plasma concentration of gabexate mesilate (ethyl-p-(6-guanidinohexanoyloxy) benzoate) methanesulfonate (GM), FOY, was measured on a high performance liquid chromatography. GM concentrations ranging from 1 to 50 micrograms/ml of whole blood were able to be determined with this method. The half-life of GM in plasma was 55 seconds and the minimum concentration of GM which affected the activated coagulation time of whole blood (ACT) was 10 micrograms/ml. This method is sensitive and accurate to provide us with the pharmacodynamic basis for the determination of the effective plasma concentration of GM with respect to its anticoagulant activity.
采用高效液相色谱法测定了甲磺酸加贝酯(4-(6-胍基己酰氧基)苯甲酸乙酯甲磺酸盐)(GM,FOY)的血浆浓度。用该方法能够测定全血中浓度范围为1至50微克/毫升的GM。GM在血浆中的半衰期为55秒,影响全血活化凝血时间(ACT)的GM最低浓度为10微克/毫升。该方法灵敏且准确,为我们确定GM抗凝活性的有效血浆浓度提供了药效学依据。