Yamada M, Hoki N, Ishikawa K, Yoshima H, Hata S, Ohkubo N, Matsuwaka R, Furubayashi K, Fukushima M, Onishi K
Br Heart J. 1984 Mar;51(3):298-305. doi: 10.1136/hrt.51.3.298.
A scintigraphic technique using indium-111 labelled platelets to detect left atrial thrombi was used in 28 patients, 14 of whom had mitral valve disease and 14 combined valve disease. Imaging was performed in the anterior, right anterior oblique (45 degrees), and left lateral views on the day of injection and thereafter at one or two day intervals for a maximum of four days. When scintiphotos obtained in two or three views 72 or 96 hours after the platelet injection showed "hot spot areas" within the left atrial pool and indium-111 activity in these areas did not decrease with time they were interpreted as positive for thrombi. Of 28 patients, seven had positive platelet images by this criterion; of these, three underwent surgery and were found to have left atrial thrombi. One patient died, and a thrombus was found at necropsy. The remaining 21 patients had normal scintiphotos; of these, seven had no thrombi at operation and one had false negative images. The diagnostic accuracy of platelet scintigraphy by this criterion of positivity in the 12 patients in whom surgical or postmortem confirmation of thrombi could be obtained was 92%. These results indicate that this technique is a promising method for detecting active left atrial thrombi.
采用铟 - 111标记血小板的闪烁扫描技术检测左心房血栓,应用于28例患者,其中14例患有二尖瓣疾病,14例患有联合瓣膜疾病。注射当天在前位、右前斜位(45度)和左侧位进行成像,此后每隔1天或2天成像一次,最多持续4天。当血小板注射后72或96小时在两三个视角获得的闪烁照片显示左心房池内有“热点区域”,且这些区域的铟 - 111活性不随时间降低时,即判定为血栓阳性。28例患者中,按此标准有7例血小板图像呈阳性;其中3例接受手术,发现有左心房血栓。1例患者死亡,尸检发现有血栓。其余21例患者闪烁照片正常;其中7例手术时无血栓,1例有假阴性图像。在12例可通过手术或尸检证实血栓的患者中,按此阳性标准,血小板闪烁扫描的诊断准确率为92%。这些结果表明,该技术是检测活动性左心房血栓的一种有前景的方法。