McMurray R G, Sheps D S, Guinan D M
J Appl Physiol Respir Environ Exerc Physiol. 1984 Feb;56(2):436-40. doi: 10.1152/jappl.1984.56.2.436.
To examine the effect of naloxone (an opiate antagonist) on exercise performance, six normal females (20-28 yr) walked on a treadmill (93.8 m/min) with the grade increasing 2.5% every 4 min until exhaustion. Each subject completed three trials: naloxone infusion (0.4 mg/ml saline), saline infusion (1 ml), and an infusion control. The order of trials was randomized and double blind. Each subject responded similarly at each submaximal stage for all three trials. The results during maximal exertion were different. Time to exhaustion was similar for all conditions, averaging 32.6 +/- 3.0 min with a maximal O2 uptake of 38.8 +/- 2.8 ml X kg-1 X min-1 and a lactate of 9.1 +/- 1.1 mmol/l. Maximal ventilation (BTPS) was 7.9 l/min less during the naloxone treatment when compared with either control or placebo trials (P less than 0.05). This difference was attributed to a 4-breath/min reduction in respiratory frequency (P less than 0.05). End-tidal CO2 partial pressure was approximately 4 Torr higher at maximum after naloxone injection. Maximal heart rates averaged 190.8 +/- 3.8 beats/min for both control and placebo trials. This was significantly greater (P less than 0.05) than the 185 +/- 2.4 beats/min recorded for the naloxone trials. Ratings of perceived exertion were 17.0 +/- 1.3 units at maximum, similar for all three trials. Despite these statistically significant cardiorespiratory differences, naloxone produced no effect on maximum O2 uptake or exercise duration.
为研究纳洛酮(一种阿片类拮抗剂)对运动能力的影响,六名正常女性(20 - 28岁)在跑步机上以93.8米/分钟的速度行走,坡度每4分钟增加2.5%,直至力竭。每名受试者完成三项试验:输注纳洛酮(0.4毫克/毫升生理盐水)、输注生理盐水(1毫升)以及输注对照。试验顺序随机且采用双盲法。在所有三项试验的每个次最大运动阶段,每名受试者的反应相似。最大运动时的结果有所不同。所有条件下的力竭时间相似,平均为32.6±3.0分钟,最大摄氧量为38.8±2.8毫升·千克⁻¹·分钟⁻¹,乳酸水平为9.1±1.1毫摩尔/升。与对照或安慰剂试验相比,纳洛酮治疗期间的最大通气量(体温、气压、饱和水蒸气条件下)低7.9升/分钟(P<0.05)。这种差异归因于呼吸频率降低4次/分钟(P<0.05)。纳洛酮注射后,最大呼气末二氧化碳分压大约高4托。对照和安慰剂试验的最大心率平均为190.8±3.8次/分钟。这显著高于纳洛酮试验记录的185±2.4次/分钟(P<0.05)。最大主观用力感觉评分为17.0±1.3分,三项试验相似。尽管存在这些具有统计学意义的心肺差异,但纳洛酮对最大摄氧量或运动持续时间没有影响。