Suppr超能文献

色甘酸钠雾化液与支气管扩张剂吸入液混合制剂的物理化学相容性

Physical-chemical compatibility of cromolyn sodium nebulizer solution--bronchodilator inhalant solution admixtures.

作者信息

Lesko L J, Miller A K

出版信息

Ann Allergy. 1984 Sep;53(3):236-8.

PMID:6433752
Abstract

Cromolyn sodium nebulizer solution, 1%, is physically and chemically compatible (stable) for up to 60 minutes when mixed in vitro with metaproterenol, isoproterenol, isoetharine, epinephrine, terbutaline, and acetylcysteine inhalant solutions, respectively. Similarly, cromolyn does not adversely affect the stability of the individual bronchodilator/mucolytic drugs in the admixtures. Adding a bronchodilator/mucolytic agent to a cromolyn nebulizer solution should not negatively influence the in vivo efficacy or safety of either active ingredient.

摘要

1%的色甘酸钠雾化液在体外分别与间羟异丙肾上腺素、异丙肾上腺素、异他林、肾上腺素、特布他林和乙酰半胱氨酸吸入溶液混合时,在物理和化学性质上具有相容性(稳定),长达60分钟。同样,色甘酸钠不会对混合物中各支气管扩张剂/黏液溶解剂的稳定性产生不利影响。向色甘酸钠雾化液中添加支气管扩张剂/黏液溶解剂不应负面影响任何一种活性成分的体内疗效或安全性。