• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Accuracy of new gas flowmeters.

作者信息

Waaben J, Brinkløv M M, Stokke D B

出版信息

Br J Anaesth. 1980 Jan;52(1):97-100. doi: 10.1093/bja/52.1.97.

DOI:10.1093/bja/52.1.97
PMID:6445740
Abstract

The accuracy of five new oxygen and nitrous oxide flowmeter units was investigated using the bubble meter method. The results were compared with those previously found in flowmeters withdrawn from clinical use. New oxygen flowmeters demonstrated less inaccuracies than old flowmeters. No differences were found between the nitrous oxide flowmeters. Unacceptable errors were demonstrated at oxygen presettings less than 1 litre min-1, suggesting the grading within this range to be of no value. Marked deviations which exceeded the limits stated by the manufacturer could still be shown at presettings greater than 1 litre min-1. If an exact FIO2 is required, continuous monitoring with a high accuracy oxygen analyser is essential, even using new flowmeters.

摘要

相似文献

1
Accuracy of new gas flowmeters.
Br J Anaesth. 1980 Jan;52(1):97-100. doi: 10.1093/bja/52.1.97.
2
Accuracy of gas flowmeters determined by the bubble meter method.
Br J Anaesth. 1978 Dec;50(12):1251-6. doi: 10.1093/bja/50.12.1251.
3
The ejector flowmeter: an evaluation of its accuracy.
Acta Anaesthesiol Scand. 1978;22(5):527-9. doi: 10.1111/j.1399-6576.1978.tb01334.x.
4
Hypoxia with a third flowmeter tube on the anaesthetic machine.麻醉机上带有第三根流量计管的低氧情况。
Anaesth Intensive Care. 1978 Nov;6(4):355-7. doi: 10.1177/0310057X7800600411.
5
Accuracy of anaesthetic gas flowmeters.麻醉气体流量计的准确性。
Br J Anaesth. 1979 Sep;51(9):907-8. doi: 10.1093/bja/51.9.907.
6
The wide-range ejector flowmeter: calibrated gas evacuation comprising both high and low gas flows.
Can Anaesth Soc J. 1984 Nov;31(6):695-8. doi: 10.1007/BF03008770.
7
Effects of xenon on the performance of various respiratory flowmeters.氙气对各种呼吸流量计性能的影响。
Anesthesiology. 1999 Feb;90(2):555-63. doi: 10.1097/00000542-199902000-00032.
8
Oxygen failure: A potential danger with air-flowmeters in anaesthetic machine with remote controlled needle valves.氧气故障:配备遥控针阀的麻醉机中的气流计存在的潜在危险。
Br J Anaesth. 1973 Nov;45(11):1165-8. doi: 10.1093/bja/45.11.1165.
9
[The accuracy of oxygen flowmeters].[氧气流量计的准确性]
Anasth Intensivther Notfallmed. 1986 Aug;21(4):226-7.
10
Oxygen flow through nasal cannulae.氧气通过鼻导管输送。
Can J Anaesth. 1996 Jun;43(6):636-9. doi: 10.1007/BF03011779.