Sergievskiĭ V S, Rusanov V P, Goncharov A I, Belinskaia A M, Teplova L L
Vestn Khir Im I I Grek. 1978 Feb;120(2):28-31.
Experimentally on 116 dogs it has been found that intravascular shunts of a big diameter or those controlled by means of extracorporal shunts ensure stable hemodynamic indices, approximately the initial ones. The isolated hypothermal perfusion protects, in its turn, the liver from an ischemic trauma and prolongs the safety period of the liver blood flow break to 40 minutes and more.