The dust retention efficiency of a model fibrous filter operated in the high inertia regime has been measured over the size range 2-22 micrometer. The results of a program to measure the influence of loading on grade efficiency are reported. It is shown that the efficiency of particle retention increases with loading initially, then falls off as the filter becomes loaded to its maximum capacity. The effect of test dust feed size distribution has also been investigated. Under some circumstances this parameter may have a critical effect on the overall efficiency. The mechanisms responsible for the observed behavior are described and their implications in fibrous filtration discussed.
在2-22微米的尺寸范围内,对处于高惯性状态下运行的模型纤维过滤器的粉尘捕集效率进行了测量。报告了一项测量负荷对分级效率影响的计划结果。结果表明,颗粒捕集效率最初随负荷增加而提高,然后随着过滤器达到最大负荷而下降。还研究了测试粉尘进料尺寸分布的影响。在某些情况下,该参数可能对整体效率产生关键影响。描述了导致观察到的行为的机制,并讨论了它们在纤维过滤中的意义。