Hyodo A, Mizukami M, Tazawa T, Togashi O
No Shinkei Geka. 1984 Mar;12(3 Suppl):311-8.
The authors' experience with the application of real-time ultrasonography during 29 and after 3 neurosurgical operations is reported. Intraoperative sonography was performed in 29 cases. The neurosurgical operations include aneurysm surgery in 13 cases, removal of intracerebral hematoma in 11 cases, neoplasm surgery in 2 cases, and so on. Moreover, sonographic examination through bone defect was performed in 3 cases after decompression craniectomy. The instrument used was an ATL (Advanced Technology Laboratories, Bellevue, WA, USA) mechanical sector scanner of which scanhead contained transducers of three frequencies: 3, 5 and 7.5 MHz. The scanhead was wrapped with a sterile rubber bag after acoustic coupling gel had been applied to the head's tip. Then the scanhead was placed on the dura and ultrasonic examination was performed. The result was that the lesion was clearly identified and localized in all cases except for three cases of mild subarachnoid hemorrhage. In addition, in the two cases of needle aspiration of cyst or hematoma, the needle was easily identified and needle aspiration was performed safely and accurately. Moreover, during aneurysm surgery, aneurysm itself was detected in two cases by the real-time ultrasonic imaging. Especially, in the case with large aneurysm of the left middle cerebral artery, the findings about the aneurysmal wall, that is to say, which part is thick and which part is thin, could be obtained. Prior to the operation of aneurysm, cerebral angiogram and computerized tomographic scan are always examined thoroughly, but information about aneurysmal wall can be rarely obtained by them.(ABSTRACT TRUNCATED AT 250 WORDS)
本文报道了作者在29例神经外科手术中及术后3例应用实时超声检查的经验。29例术中进行了超声检查。神经外科手术包括13例动脉瘤手术、11例脑内血肿清除术、2例肿瘤手术等。此外,3例减压开颅术后通过骨缺损进行了超声检查。使用的仪器是一台美国华盛顿州贝尔维尤市先进技术实验室(ATL)的机械扇形扫描仪,其探头包含3、5和7.5兆赫三种频率的换能器。在探头尖端涂抹声耦合凝胶后,用无菌橡胶袋包裹探头。然后将探头置于硬脑膜上进行超声检查。结果是,除3例轻度蛛网膜下腔出血外,所有病例均能清晰识别和定位病变。此外,在2例囊肿或血肿穿刺抽吸病例中,能轻松识别穿刺针,并安全准确地进行了穿刺抽吸。而且,在动脉瘤手术中,实时超声成像在2例中检测到了动脉瘤本身。特别是在左大脑中动脉大动脉瘤病例中,可获得有关动脉瘤壁的情况,即哪部分厚哪部分薄。在动脉瘤手术前,总是要彻底检查脑血管造影和计算机断层扫描,但它们很少能获得有关动脉瘤壁的信息。(摘要截选至250词)