Kramer E L, Sanger J J
Eur J Nucl Med. 1984;9(8):345-50. doi: 10.1007/BF00252867.
Methods for creating ventilation/perfusion ratio images have been reported previously using radioxenon. With the availability of 81mKr gas, corresponding ventilation and perfusion views in multiple projections to evaluate for V/Q mismatch may be performed more readily. A technique for the creation of a functional V/Q ratio image to highlight V/Q mismatches to aid in the evaluation of pulmonary embolism is described. By removing nonpertinent and distracting information and by converting a 'cold spot' imaging modality to a 'hot spot' modality, these functional images aid in the synthesis of the information provided by the ventilation and perfusion images. The limitations due to technical artifacts and the advantages of using these functional images are described.
此前已有报道使用放射性氙气创建通气/灌注比图像的方法。随着81mKr气体的出现,通过多个投影获取相应的通气和灌注视图以评估通气/血流不匹配可能会更容易实现。本文描述了一种创建功能性通气/灌注比图像的技术,该图像可突出通气/血流不匹配,有助于肺栓塞的评估。通过去除无关和干扰信息,并将“冷区”成像模式转换为“热区”模式,这些功能性图像有助于综合通气和灌注图像提供的信息。文中还描述了技术伪影带来的局限性以及使用这些功能性图像的优势。