The patency of the maxillary ostium can investigated by measurement of velocity and of presure difference with a new equipment of hot film anemometry and by strain gauges. This studies were performed during sinuscopy. The values are registered on a way-time recorder. The measurement of velocity in the maxillary sinus is more preferable than the measurement of pressure because we need no extraantal point of reference pressure: nose-sinus: difference pressure: sinus atmosphere. Both methods, the measurement of air flow and pressure difference, can proof the patency of the maxillary ostium. Examples are given from open partial patent ostium and from obstructed one.

摘要

上颌窦口的通畅情况可通过使用新型热膜风速仪设备和应变片测量流速及压力差来进行研究。这些研究是在鼻窦镜检查期间进行的。测量值记录在路程-时间记录仪上。在上颌窦中测量流速比测量压力更可取,因为我们不需要额外的鼻腔外参考压力点:鼻-窦压差:窦内气压。测量气流和压力差这两种方法都可以证明上颌窦口的通畅情况。文中给出了开放部分通畅窦口和阻塞窦口的示例。