Tokuma Y, Shiozaki Y, Noguchi H
J Chromatogr. 1984 Nov 28;311(2):339-46. doi: 10.1016/s0378-4347(00)84727-1.
A sensitive method for the determination of a new cephalosporin in human serum and urine is described. The sensitivity of the procedure is derived from a high-performance liquid chromatographic separation which utilizes the different selectivities of two columns. Partial separation of the agent from deproteinized serum or diluted urine is achieved by an anion-exchange column. To concentrate the large volume of the eluent fraction containing the compound from the anion-exchange column, a reversed-phase short column is placed between the anion-exchange column and a reversed-phase analytical column. The separation is completed by switching the eluent fraction containing the compound from the second column to the analytical column. The compound is detected by ultraviolet absorption at 295 nm. Quantitation is possible down to 0.05 microgram/ml using 300 microliter of serum and down to 0.5 microgram/ml using 50 microliter of urine. The coefficients of variation of the method are 6.8% and 0.6% in serum when spiked at the 0.05 microgram/ml and 1.0 microgram/ml level, respectively. One assay can be completed in 16 min. Serum levels and urinary excretion data obtained with this method are given for three healthy volunteers who had received a 100-mg oral dose of the compound.
本文描述了一种测定人血清和尿液中一种新型头孢菌素的灵敏方法。该方法的灵敏度源于高效液相色谱分离,此分离利用了两根色谱柱不同的选择性。通过阴离子交换柱可实现该药物与脱蛋白血清或稀释尿液的部分分离。为了浓缩来自阴离子交换柱的含有该化合物的大量洗脱液馏分,在阴离子交换柱和反相分析柱之间放置一根反相短柱。通过将含有该化合物的洗脱液馏分从第二根柱切换到分析柱来完成分离。该化合物通过在295nm处的紫外吸收进行检测。使用300微升血清时,定量下限可达0.05微克/毫升,使用50微升尿液时,定量下限可达0.5微克/毫升。该方法在血清中添加0.05微克/毫升和1.0微克/毫升水平时的变异系数分别为6.8%和0.6%。一次测定可在16分钟内完成。给出了三名口服100毫克该化合物的健康志愿者用此方法获得的血清水平和尿排泄数据。