Désage M, Soubeyrand J, Soun A, Brazier J L, Georges Y
J Chromatogr. 1984 Dec 12;336(2):285-91. doi: 10.1016/s0378-4347(00)85151-8.
An automated gas chromatographic--mass spectrometric assay for theophylline is described. Theophylline is extracted from plasma or urine (50 microliter) and transformed into an N-pentyl derivative. The internal standard used for quantitation is [1,3-15N, 2-13C]theophylline. The detection is performed by monitoring the molecular ions 250 for theophylline and 253 for the internal standard with a quadrupole mass specific detector HP 5790 A. The system has been fully automated: injection, calibration, assay, calculation. The method shows excellent analytical parameters: linearity between 2 and 40 micrograms/ml; day-to-day reproducibility 1.82% for a concentration of 15 micrograms/ml; repeatability 0.75% (15 micrograms/ml) and 0.33% (30 micrograms/ml). Accuracy is also excellent. Due to the use of an internal standard labelled with stable isotopes, the specificity and high analytical quality of the method make it useful as a reference method to compare with routine theophylline assays.
本文描述了一种用于测定茶碱的自动气相色谱 - 质谱分析法。从血浆或尿液(50微升)中提取茶碱,并将其转化为N - 戊基衍生物。用于定量的内标是[1,3 - ¹⁵N,2 - ¹³C]茶碱。通过使用四极杆质量特异性检测器HP 5790 A监测茶碱的分子离子250和内标的分子离子253来进行检测。该系统已完全自动化:进样、校准、分析、计算。该方法显示出优异的分析参数:在2至40微克/毫升之间呈线性;对于15微克/毫升的浓度,日间重现性为1.82%;重复性为0.75%(15微克/毫升)和0.33%(30微克/毫升)。准确性也非常出色。由于使用了稳定同位素标记的内标,该方法的特异性和高分析质量使其可用作与常规茶碱测定法进行比较的参考方法。