A simple stagnation flow method for the determination of platelet adhesivity has been developed. The sensitivity of the method to its main operational parameters was tested, resulting in recommended standard flow conditions. The method was shown to be dependent on the surface properties of the test slide, on which platelets are deposited, thus proving its suitability to elucidate variations in the surface interaction of the platelets. Normal values were established for males and females.
已开发出一种用于测定血小板黏附性的简单滞流法。测试了该方法对其主要操作参数的敏感性,得出了推荐的标准流动条件。结果表明该方法取决于血小板沉积的测试载玻片的表面特性,从而证明其适用于阐明血小板表面相互作用的变化。确定了男性和女性的正常值。