Sixty-eight consecutive patients (9 males, 59 females) referred for symptoms alleged to be caused by oral galvanism were investigated according to a standardized examination program including clinical examination, epicutaneous patch test with dental materials, haematologic screening, salivary test, calculation of currents created at metallic contacts between restorative materials and testing of electrical taste thresholds. No clinical entity could be identified but recognized clinical conditions that could possibly explain the complaints for which the patients were referred were prevalent. The most common symptoms reported were a smarting sensation in the mouth (71%) and different distant symptoms (47%). As regards oral signs, some of them showed similar prevalences as have been found in a general Swedish population. The main exception was changes at the apex of the tongue - found in 15%. Allergic skin reactions to dental materials were found among 25% of the patients. Mean values of blood and saliva parameters did not differ from what is considered normal. The distribution of currents created by contacting dental metallic restorations showed no deviation from the corresponding currents calculated in a control group. The median value for lowest electrical taste threshold in the group of referred patients was significantly lower than in a control group.
对68例因据称由口腔电流刺激引起症状而前来就诊的连续患者(9例男性,59例女性),按照标准化检查程序进行了调查,该程序包括临床检查、用牙科材料进行皮肤斑贴试验、血液学筛查、唾液检测、计算修复材料之间金属接触产生的电流以及测试电味觉阈值。未发现可明确的临床实体,但常见的、可能解释患者前来就诊主诉的临床情况很普遍。报告的最常见症状是口腔刺痛感(71%)和不同的远处症状(47%)。至于口腔体征,其中一些的患病率与瑞典普通人群中的发现相似。主要例外是舌尖部改变——发现率为15%。25%的患者对牙科材料有皮肤过敏反应。血液和唾液参数的平均值与正常范围无差异。接触牙科金属修复体产生的电流分布与对照组计算的相应电流无偏差。前来就诊患者组中最低电味觉阈值的中位数显著低于对照组。