Reiber J H, Lie S P, Simoons M L, Hoek C, Gerbrands J J, Wijns W, Bakker W H, Kooij P P
J Nucl Med. 1983 Dec;24(12):1099-107.
A fully automated procedure for the computation of left-ventricular ejection fraction (EF) from cardiac-gated Tc-99m blood-pool (GBP) scintigrams with fixed, dual, and variable ROI methods is described. By comparison with EF data from contrast ventriculography in 68 patients, the dual-ROI method (separate end-diastolic and end-systolic contours) was found to be the method of choice; processing time was 2 min. Success score of dual-ROI procedure was 92% as assessed from 100 GBP studies. Overall reproducibility of data acquisition and analysis was determined in 12 patients. Mean value and standard deviation of differences between repeat studies (average time interval 27 min) were 0.8% and 4.3% EF units, respectively, (r = 0.98). We conclude that left-ventricular EF can be computed automatically from GBP scintigrams with minimal operator-interaction and good reproducibility; EFs are similar to those from contrast ventriculography.
描述了一种通过固定、双感兴趣区(ROI)和可变ROI方法从心脏门控Tc-99m血池(GBP)闪烁图计算左心室射血分数(EF)的全自动程序。通过与68例患者的对比心室造影的EF数据进行比较,发现双ROI方法(分别为舒张末期和收缩末期轮廓)是首选方法;处理时间为2分钟。根据100项GBP研究评估,双ROI程序的成功率为92%。在12例患者中确定了数据采集和分析的总体可重复性。重复研究(平均时间间隔27分钟)之间差异的平均值和标准差分别为0.8%和4.3%EF单位(r = 0.98)。我们得出结论,左心室EF可以通过GBP闪烁图自动计算,操作互动最少且具有良好的可重复性;EF与对比心室造影的结果相似。