Suppr超能文献

低浓度抗生素对人同种异体心脏瓣膜的消毒

Disinfection of human heart valve allografts with antibiotics in low concentration.

作者信息

Strickett M G, Barratt-Boyes B G, MacCulloch D

出版信息

Pathology. 1983 Oct;15(4):457-62. doi: 10.3109/00313028309085175.

Abstract

Antibiotic disinfection of allograft heart valves is now an established procedure. A new low-concentration, broad-spectrum mixture of antibiotics was formulated and used successfully to disinfect 58 of 60 human aortic and pulmonary valves after 48 h exposure at 4 degrees C. The antibiotics included were cefoxitin 240 mcg/ml, lincomycin 120 mcg/ml, polymyxin B 100 mcg/ml, vancomycin 50 mcg/ml and amphotericin B 25 mcg/ml. Microorganisms isolated from experimental tissue and from clinical valves before treatment were tested for sensitivity to these antibiotics and were found to be sensitive to one or more. One isolate of Pseudomonas spp. showed decreased sensitivity to polymyxin B, and was found to have a minimum bactericidal concentration of 70 mcg/ml. Results indicated this antibiotic mixture had superior antibacterial efficiency to that in routine clinical use for the past 13 yr.

摘要

同种异体心脏瓣膜的抗生素消毒现在已是一种既定程序。一种新的低浓度、广谱抗生素混合物被配制出来,并成功用于60个主动脉瓣和肺动脉瓣中的58个,在4℃下暴露48小时后进行消毒。所使用的抗生素包括头孢西丁240微克/毫升、林可霉素120微克/毫升、多粘菌素B 100微克/毫升、万古霉素50微克/毫升和两性霉素B 25微克/毫升。对从实验组织和治疗前的临床瓣膜中分离出的微生物进行了这些抗生素的敏感性测试,发现它们对一种或多种抗生素敏感。一株假单胞菌属菌株对多粘菌素B的敏感性降低,其最低杀菌浓度为70微克/毫升。结果表明,这种抗生素混合物的抗菌效率优于过去13年常规临床使用的抗生素。