• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Computer simulations of speckle in B-scan images.

作者信息

Foster D R, Arditi M, Foster F S, Patterson M S, Hunt J W

出版信息

Ultrason Imaging. 1983 Oct;5(4):308-30. doi: 10.1177/016173468300500403.

DOI:10.1177/016173468300500403
PMID:6686898
Abstract

The granularity or speckle in medical ultrasound images tends to mask the presence of small lesions. As well, artifactual filling in of anechoic regions such as cysts, reduces the diagnostic potential of the images. These effects depend not only on the acoustic properties of the tissue but also are strongly influenced by the imaging system, especially the transducer geometry. To study the effect of the transducer on the final B-scan image, a computer model has been developed simulating the interaction of ultrasound with a simple scattering medium. This model, incorporating the position dependence of the point response of the transducer, is based on single scattering from a collection of points positioned randomly in a three-dimensional volume. Using this approach, B-scan images showing speckle have been generated for different transducer geometries. Inclusion of a 2.6 mm void mimicking a cyst within the three-dimensional scattering volume has allowed us to predict the cyst contrast in the image for the different transducer systems. Experimental B-scan images of a scattering phantom were obtained using the different pulse echo systems. Quantitative assessment using first and second order statistics of the images shows good agreement between experiment and theory.

摘要

相似文献

1
Computer simulations of speckle in B-scan images.
Ultrason Imaging. 1983 Oct;5(4):308-30. doi: 10.1177/016173468300500403.
2
A three dimensional model for generating the texture in B-scan ultrasound images.
Ultrason Imaging. 1983 Jul;5(3):253-79. doi: 10.1177/016173468300500305.
3
Quantitative contrast measurements in B-mode images comparison between experiment and theory.
Ultrasound Med Biol. 1986 Mar;12(3):197-208. doi: 10.1016/0301-5629(86)90310-8.
4
Simulation of B-scan images from two-dimensional transducer arrays: Part I--Methods and quantitative contrast measurements.二维换能器阵列B扫描图像的模拟:第一部分——方法与定量对比度测量
Ultrason Imaging. 1992 Oct;14(4):323-43. doi: 10.1177/016173469201400401.
5
A wavefield extrapolation method for simulating B-scan images.
Ultrason Imaging. 1987 Jul;9(3):171-9. doi: 10.1177/016173468700900303.
6
Quantitative tests of a three-dimensional gray scale texture model.
Ultrason Imaging. 1985 Jul;7(3):252-63. doi: 10.1177/016173468500700305.
7
Simulation of B-scan images from two-dimensional transducer arrays: Part II--Comparisons between linear and two-dimensional phased arrays.二维换能器阵列B扫描图像模拟:第二部分——线性相控阵与二维相控阵的比较
Ultrason Imaging. 1992 Oct;14(4):344-53. doi: 10.1177/016173469201400402.
8
Parametric ultrasound imaging from backscatter coefficient measurements: image formation and interpretation.基于背向散射系数测量的参数超声成像:图像形成与解读
Ultrason Imaging. 1990 Oct;12(4):245-67. doi: 10.1177/016173469001200402.
9
Computerized ultrasound echo tomography of the breast.
Eur J Radiol. 1982 Feb;2(1):78-87.
10
Free of speckle ultrasound images of small tissue structures.无斑点的小组织结构超声图像。
Ultrasonics. 2002 Nov;40(9):983-96. doi: 10.1016/s0041-624x(02)00386-4.

引用本文的文献

1
Insights into photoacoustic speckle and applications in tumor characterization.光声散斑研究及其在肿瘤特征描述中的应用
Photoacoustics. 2019 Apr 5;14:37-48. doi: 10.1016/j.pacs.2019.02.002. eCollection 2019 Jun.
2
Fundamental correlation lengths of coherent speckle in medical ultrasonic images.医学超声图像中相干散斑的基本相关长度。
IEEE Trans Ultrason Ferroelectr Freq Control. 1988;35(1):34-44. doi: 10.1109/58.4145.