Suppr超能文献

Substrate specificity of tissue plasminogen activator and urokinase as determined with synthetic chromogenic substrates.

作者信息

Matsuo O, Sakai T, Takakura Y, Mihara H

出版信息

Jpn J Physiol. 1983;33(6):1031-7. doi: 10.2170/jjphysiol.33.1031.

Abstract

Three different synthetic chromogenic substrates )H-glutamylglycyl-L-arginine-p-nitroanilide (S-2227), pyro-glutamyl-glycyl-L-arginine-p-nitroanilide (S-2444), and H-D-isoleucyl-L-prolyl-L-arginine-p-nitroanilide (S-2288] were investigated for use in the measurement of plasminogen activator activity with high molecular weight urokinase (H-UK), low molecular weight urokinase (L-UK), and tissue plasminogen activator (TPA). The three substrates were hydrolyzed by both TPA-type and UK-type plasminogen activator. As regards the amidolytic activity of S-2227, TPA exhibited a weaker amidolytic activity, and L-UK a stronger activity. In the case of the amidolytic activity of S-2444, no great difference between the three activators was observed in terms of Vmax. As regards the amidolytic activity of S-2288, L-UK exhibited a stronger activity, and TPA a weaker activity. It is suggested that the molecular size of the synthetic chromogenic substrate was too small when compared to natural substrate (fibrin), and therefore that fibrin-binding sites around the catalytic site in TPA are not recognized.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验