Suppr超能文献

冠状动脉闭塞后再灌注犬心肌中铊-201的动力学

Kinetics of thallium-201 in reperfused canine myocardium after coronary artery occlusion.

作者信息

Okada R D

出版信息

J Am Coll Cardiol. 1984 May;3(5):1245-51. doi: 10.1016/s0735-1097(84)80183-7.

Abstract

To study the kinetics of thallium-201 in nonsalvaged acutely infarcted myocardium and salvaged myocardium, the tracer was administered after experimental left anterior descending coronary artery reperfusion 2 hours after occlusion. In 19 dogs, thallium activity was then monitored for 4 hours in the reperfused anterior wall and normal posterior wall using miniature cadmium telluride radiation detectors. After sacrifice, 13 of the dogs were found to have an infarcted anterior wall by triphenyltetrazolium-chloride staining. In these dogs, mean (+/- standard deviation) fractional 4 hour thallium clearance was 0.33 +/- 0.08 for the infarct zone and 0.15 +/- 0.06 for the normal control zone (p less than 0.001). When computer-modeled, the clearance curve from the infarct zone was biexponential. The second exponential clearance curve from the infarct zone began 19.1 +/- 3.2 minutes after tracer administration, and was indistinguishable from the monoexponential clearance curve from the normal control zone. Thallium clearance from the blood pool was triexponential, the final exponential clearance curve being indistinguishable from the normal control zone clearance curve. Six dogs were found to have a salvaged noninfarcted anterior wall by triphenyltetrazolium-chloride staining. In these dogs, mean fractional 4 hour thallium clearance was 0.20 +/- 0.07 for the reperfused zone, and 0.19 +/- 0.08 for the normal control zone (p = NS). When computer-modeled, clearance curves for the reperfused and control zones were monoexponential. The monoexponential clearance curve for the salvaged reperfused zone was indistinguishable from the monoexponential clearance curve for normal myocardium.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

为研究铊-201在未挽救的急性梗死心肌和挽救心肌中的动力学,在实验性左前降支冠状动脉闭塞2小时后再灌注后给予示踪剂。在19只犬中,然后使用微型碲化镉辐射探测器在再灌注的前壁和正常后壁监测铊活性4小时。处死后,通过氯化三苯基四氮唑染色发现其中13只犬有梗死的前壁。在这些犬中,梗死区4小时铊清除分数的平均值(±标准差)为0.33±0.08,正常对照区为0.15±0.06(p<0.001)。经计算机模拟,梗死区的清除曲线为双指数曲线。梗死区的第二条指数清除曲线在示踪剂给药后19.1±3.2分钟开始,与正常对照区的单指数清除曲线无差异。血池铊清除为三指数曲线,最后的指数清除曲线与正常对照区清除曲线无差异。通过氯化三苯基四氮唑染色发现6只犬有挽救的非梗死前壁。在这些犬中,再灌注区4小时铊清除分数的平均值为0.20±0.07,正常对照区为0.19±0.08(p=无显著性差异)。经计算机模拟,再灌注区和对照区的清除曲线为单指数曲线。挽救的再灌注区的单指数清除曲线与正常心肌的单指数清除曲线无差异。(摘要截断于250字)

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验