Suppr超能文献

Serous fluid leakage: a complication following the modified Blalock-Taussig shunt.

作者信息

LeBlanc J, Albus R, Williams W G, Moes C A, Wilson G, Freedom R M, Trusler G A

出版信息

J Thorac Cardiovasc Surg. 1984 Aug;88(2):259-62.

PMID:6748719
Abstract

Polytetrafluoroethylene tubular grafts are useful in performing a systemic-to-pulmonary artery shunt (modified Blalock-Taussig). They allow a controlled-volume shunt, avoid kinking of the pulmonary artery, and preserve distal flow in the subclavian artery. Unfortunately, occasionally excessive serous fluid will drain through the interstices of the fabric. This results in excessive and prolonged chest tube drainage and/or localized seroma formation around the graft. This complication occurred in 26 children, an incidence of 18.8% of the 138 modified Blalock-Taussig operations. Repeat thoracotomy was required in four of these children--for evacuation of seroma mass in three and for relief of cardiac tamponade in one. Four other children required reinsertion of pleural or pericardial chest drains for excessive serous drainage persisting as long as 6 weeks after operation. Wrapping of the graft with silicone sheeting to facilitate subsequent takedown of the shunt led to seroma formation in five of nine children. We believe this practice should be abandoned. Excessive drainage of serous fluid through the interstices of PTFE grafts in almost 20% of our patients has compromised an otherwise satisfactory result of the modified Blalock-Taussig operation.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验