Abstract

I analyzed for free and sulfate-conjugated catecholamines and DOPA (3,4-dihydroxyphenylalanine) in four aliquots of a single plasma pool with use of Upjohn's "Cat-A-Kit" (catecholamines radioenzymatic assay kit [3H]. One aliquot was a clear plasma control; the others were supplemented with different concentrations of lysed human erythrocytes, to investigate possible interference by hemolysis with analysis for norepinephrine, epinephrine, dopamine, or DOPA in plasma. I observed no statistically significant difference that could be attributed to the degree of hemolysis between control and treatment groups for DOPA or any catecholamine fraction. Hemolysis in plasma from improper collection or processing techniques apparently does not preclude accurate and precise quantitation of free or sulfate-conjugated catecholamines or DOPA with the Cat-A-Kit.

摘要

我使用Upjohn公司的“Cat - A - Kit”(儿茶酚胺放射酶分析法试剂盒[³H])对单个血浆样本的四个等分试样中的游离和硫酸结合型儿茶酚胺及多巴(3,4 - 二羟基苯丙氨酸)进行了分析。一份等分试样为清亮的血浆对照;其他试样则添加了不同浓度的裂解人红细胞,以研究溶血对血浆中去甲肾上腺素、肾上腺素、多巴胺或多巴分析的可能干扰。对于多巴或任何儿茶酚胺组分,我观察到对照组和处理组之间因溶血程度导致的差异无统计学意义。因采集或处理技术不当导致的血浆溶血显然并不妨碍使用Cat - A - Kit对游离或硫酸结合型儿茶酚胺或多巴进行准确和精确的定量。