Suppr超能文献

血细胞分离机上进行强化血浆置换后的凝血异常。II. 对因子I、II、V、VII、VIII、IX、X及抗凝血酶III的影响

Coagulation abnormalities following intensive plasma exchange on the cell separator. II. Effects on factors I, II, V, VII, VIII, IX, X and antithrombin III.

作者信息

Chirnside A, Urbaniak S J, Prowse C V, Keller A J

出版信息

Br J Haematol. 1981 Aug;48(4):627-34. doi: 10.1111/j.1365-2141.1981.00627.x.

Abstract

The effects of intensive plasma exchange on the circulating levels of coagulation factors I, II, V, VII, VIII, IX, X and antithrombin III were determined. During courses of daily exchange marked cumulative reductions of coagulation factors may occur, particularly in the case of factors I, II and X, although usually remaining above the levels considered adequate for haemostasis. The extent of cumulative reduction and subsequent recovery differed for patients with different diseases. While antithrombin III levels were reduced during plasma exchange the results suggest that this may be partly due to consumption as well as physical removal. The very low incidence of haemorrhagic sequelae and absence of thrombotic events following plasma exchange at this Centre is explained by the maintenance of adequate levels of coagulation factors and of antithrombin III even during courses of daily plasma exchange.

摘要

测定了强化血浆置换对凝血因子I、II、V、VII、VIII、IX、X及抗凝血酶III循环水平的影响。在每日进行血浆置换的疗程中,凝血因子可能会出现显著的累积性降低,尤其是因子I、II和X,尽管通常仍高于被认为足以实现止血的水平。不同疾病患者的累积降低程度及随后的恢复情况有所不同。虽然血浆置换期间抗凝血酶III水平降低,但结果表明这可能部分归因于消耗以及物理清除。本中心血浆置换后出血后遗症发生率极低且无血栓形成事件,这是由于即使在每日进行血浆置换的疗程中,凝血因子和抗凝血酶III水平仍维持在足够水平。