Suppr超能文献

[冠状动脉造影术中的静脉硝酸甘油试验]

[The intravenous nitroglycerin test during coronary angiography].

作者信息

Bory M, Egre A, Sacerdote P, Bénichou M, Cardella C, Djiane P, Serradimigni A

出版信息

Arch Mal Coeur Vaiss. 1981 Jun;74(6):675-84.

PMID:6794489
Abstract

The effects of intravenous nitroglycerin (Lenitral) on the calibre of coronary arteries and their lesions was studied in 100 consecutive patients undergoing coronary angiography. The coronary arteries were divided into segments (3 for the right coronary, 2 for the left anterior descending, and 2 for the circumflex artery). 510 segments were assessed (279 normal, and 231 pathological). The diameter of each was measured through the mid point before and after injection of a bolus of 0.3 mg nitroglycerin. The calibre of the coronary segments increased in 325 cases (63.7%). In 49 cases, the increase was greater than 50%. It remained the same in 151 cases (29,6%) and decreased in 84 cases (6,7%). The average increase in calibre was 16% (p less than 0.01). This had little relation to the artery under study, the location of the segment or whether the segment was pathological or normal. However, two findings were of interest: - the percentage of segments which increased their calibre was significantly higher in the normal segments (191 out of 279 cases, 68%) than in the pathological segments (134 out of 231 cases, 58%) (p less than 0.01). - Coronary lesions may change in appearance: images of stenosis or obstruction completely regressed in 4 cases, the degree of stenosis seemed to increase in 11 cases because of dilatation of the coronary vessel proximal and distal to the narrowing, and distal vessels appeared much more dilated in 5 cases. The factors which seem to affect the vasomotor response are multiple, and include the state of the arterial wall, the presence of vasodilatation or vasoconstriction prior to injection and the mode of administration of the nitroglycerin. The test should be performed by intravenous or intracoronary injection at the end of coronary angiography so as not to mask spastic phenomena. Some errors in the interpretation of the degree of stenosis or the quality of the distal post-stenotic coronary bed could thus be avoided.

摘要

对100例连续接受冠状动脉造影的患者研究了静脉注射硝酸甘油(Lenitral)对冠状动脉管径及其病变的影响。冠状动脉被分为节段(右冠状动脉3个节段,左前降支2个节段,回旋支2个节段)。共评估了510个节段(279个正常节段,231个病变节段)。在注射0.3mg硝酸甘油团注前后,通过每个节段的中点测量其直径。325例(63.7%)冠状动脉节段管径增大。49例增大超过50%。151例(29.6%)管径保持不变,84例(6.7%)管径减小。管径平均增大16%(p<0.01)。这与所研究的动脉、节段位置以及节段是病变还是正常关系不大。然而,有两个发现值得关注:-正常节段中管径增大的节段百分比(279例中的191例,68%)显著高于病变节段(231例中的134例,58%)(p<0.01)。-冠状动脉病变外观可能改变:4例狭窄或阻塞影像完全消退,11例因狭窄近端和远端冠状动脉血管扩张导致狭窄程度似乎增加,5例远端血管明显更扩张。似乎影响血管运动反应的因素是多方面的,包括动脉壁状态、注射前血管舒张或收缩的存在以及硝酸甘油的给药方式。该试验应在冠状动脉造影结束时通过静脉或冠状动脉内注射进行,以免掩盖痉挛现象。从而可以避免在狭窄程度或狭窄后远端冠状动脉床质量的解释上出现一些错误。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验