Suppr超能文献

用于促甲状腺激素释放激素放射免疫分析的人尿液样本的高压液相色谱纯化

High pressure liquid chromatography purification of human urinary samples for thyrotropin-releasing hormone radioimmunoassay.

作者信息

Leppäluoto J, Suhonen A S

出版信息

J Clin Endocrinol Metab. 1982 May;54(5):914-8. doi: 10.1210/jcem-54-5-914.

Abstract

Urine samples from healthy adult subjects and patients who had received TRH orally were prepurified in SP-Sephadex-C-25 cation exchange chromatography, subjected to reverse phase high pressure liquid chromatography (HPLC) starting with 0.01 M ammonium acetate, pH 4, followed by 1%/min gradient of acetonitrile or isopropanol and assayed in a TRH RIA. Two TRH immunoreactive peaks (A and B) were detected by HPLC with an RP-8 column, peak A eluting at 4-10 min and B at 12-14 min. Serial dilutions of peak B produced a line parallel with synthetic TRH by RIA. Synthetic TRH added to urinary samples and urinary TRH immunoreactivity from TRH-treated patients were eluted at 12-14 min. These results suggest that peak B represents endogenous urinary TRH. Urinary TRH levels of eight normal human males and four females were 5.0 +/- 3.4 pg/ml and 5.2 +/- 1.2 pg/ml (mean +/- SD). These values are many times lower than those presented in previous studies.

摘要

来自健康成年受试者和口服促甲状腺激素释放激素(TRH)患者的尿液样本,先在SP-葡聚糖凝胶-C-25阳离子交换色谱中进行预纯化,然后用0.01M乙酸铵(pH4)进行反相高压液相色谱(HPLC),接着以1%/分钟的乙腈或异丙醇梯度洗脱,并在TRH放射免疫分析(RIA)中进行测定。使用RP-8柱的HPLC检测到两个TRH免疫反应峰(A和B),峰A在4 - 10分钟洗脱,峰B在12 - 14分钟洗脱。峰B的系列稀释液通过RIA产生与合成TRH平行的曲线。添加到尿液样本中的合成TRH以及来自TRH治疗患者的尿液TRH免疫反应性在12 - 14分钟洗脱。这些结果表明峰B代表内源性尿液TRH。8名正常男性和4名女性的尿液TRH水平分别为5.0±3.4pg/ml和5.2±1.2pg/ml(平均值±标准差)。这些值比先前研究中的值低很多倍。