Quantitative analysis of albuterol in human plasma by combined gas chromatography chemical ionization mass spectrometry.

作者信息

Weisberger M, Patrick J E, Powell M L

出版信息

Biomed Mass Spectrom. 1983 Oct;10(10):556-8. doi: 10.1002/bms.1200101005.

Abstract

A highly sensitive and specific quantitative assay for the determination of albuterol in human plasma, based on selected ion monitoring gas chromatography chemical ionization mass spectrometry, has been developed. The [MH]+ ions from the tri-TMS derivatives of albuterol (m/z 456) and the internal standard (2H3)albuterol (m/z 459), were assayed simultaneously by selected ion monitoring. The lower limit of quantitation is 0.25 ng ml-1 and the average assay precision (CV) for albuterol concentrations ranging from 0.25 ng ml-1 to 25 ng ml-1 is approximately 4%. This method is currently being employed for the routine quantitation of albuterol in plasma following the administration of doses therapeutically effective to man.