Daniels D L, Williams A L, Syvertsen A, Gager W E, Harris G J
AJNR Am J Neuroradiol. 1982 Mar-Apr;3(2):181-3.
Optic nerve sheath meningiomas and optic nerve gliomas can be difficult to differentiate by computed tomography (CT). Three patients with optic nerve sheath meningiomas were studied with a CT/T 8800 scanner with 1.5-mm-thick axial sections and intravenous contrast material. In each case, an abnormal optic nerve sheath was identified by CT. A soft-tissue mass arose from one side of the sheath in one patient, and the entire sheath was enlarged in two patients. This provides a basis for distinguishing optic nerve sheath meningioma from optic nerve glioma.
视神经鞘膜瘤和视神经胶质瘤通过计算机断层扫描(CT)可能难以区分。对3例视神经鞘膜瘤患者使用CT/T 8800扫描仪进行了研究,扫描层厚为1.5毫米的轴向层面,并使用了静脉造影剂。在每例患者中,CT均发现视神经鞘异常。1例患者的鞘膜一侧出现软组织肿块,2例患者的整个鞘膜均增大。这为区分视神经鞘膜瘤和视神经胶质瘤提供了依据。