Mariona F G, Yee H, Espy M J
South Med J. 1983 Feb;76(2):166-9. doi: 10.1097/00007611-198302000-00006.
In assessing fetal lung maturity, an amniotic fluid profile, consisting of a total phospholipid (as phosphorus) (TPP) and total lecithin (LT) concentration, has been shown to yield a predictive accuracy of 97.5% with a false-negative rate of 2.4%. The LT had a range of specificity of 93% to 99%, whereas the one for the TPP was 88% to 96%. The cut-off values were 0.14 mg P/dl and 3.5 mg lecithin/dl of amniotic fluid. The analytical variables for laboratory tests for measuring amniotic fluid phospholipids led to the development of the quantitative tests used for this study. The proposed profile appears to offer the clinician an excellent means of judging how to manage the high-risk pregnancy.
在评估胎儿肺成熟度时,由总磷脂(以磷计)(TPP)和总卵磷脂(LT)浓度组成的羊水分析指标已被证明具有97.5%的预测准确率和2.4%的假阴性率。LT的特异性范围为93%至99%,而TPP的特异性范围为88%至96%。临界值分别为羊水0.14mg磷/分升和3.5mg卵磷脂/分升。用于测量羊水磷脂的实验室检测分析变量促成了本研究中所使用的定量检测方法的发展。所提出的分析指标似乎为临床医生判断如何处理高危妊娠提供了一种极佳的方法。