Collimator artifacts may be present within the images produced by collimators whose septal width approaches the inherent resolution of the gamma-camera system. As the inherent resolution of the gamma-camera is improved, collimator artifacts become more prominent. The purpose of this study is to eliminate collimator artifacts from gamma-camera images. To eliminate the septum effect produced by high-energy parallel-hole collimators with thick septa, the following method was used: X and Y signals from the detector are made to ride on the triangular waves changing periodically, and resultant position signals obtained by this processing are applied to the corresponding deflection circuits in the CRT display. The oscillation amplitude of processed position signals can be regulated by the frequency and amplitude of the triangular waves. Regulation of the oscillation amplitude of position signals, which would produce maximum reduction of collimator artifacts, was to approach the spatial frequency responses of the overall processed line spread functions obtained experimentally to those of the Gaussian functions with FWHM equal to the geometric resolution calculated from the equation given by Gerber and Miller. In images of a pancreas phantom containing 131I, collimator artifacts were clearly seen in the unprocessed case, but were eliminated in the processed case.
准直器伪影可能出现在由间隔宽度接近伽马相机系统固有分辨率的准直器所产生的图像中。随着伽马相机固有分辨率的提高,准直器伪影变得更加明显。本研究的目的是消除伽马相机图像中的准直器伪影。为了消除由具有厚间隔的高能平行孔准直器产生的间隔效应,采用了以下方法:使来自探测器的X和Y信号叠加在周期性变化的三角波上,并将通过该处理获得的合成位置信号施加到阴极射线管显示器中的相应偏转电路。处理后的位置信号的振荡幅度可通过三角波的频率和幅度进行调节。调节位置信号的振荡幅度以最大程度减少准直器伪影,是使实验获得的整体处理后的线扩展函数的空间频率响应接近半高宽等于由格伯和米勒给出的公式计算出的几何分辨率的高斯函数的空间频率响应。在含有131I的胰腺模型图像中,未处理的情况下准直器伪影清晰可见,但处理后的情况下伪影被消除。