THe main metabolite of prostaglandin E2 (PGE2) 13,14-dihydro-15-keto-PGE2 readily dehydrates and can subsequently form a cyclic derivative. This problem can be overcome by the immediate formation of oximes of the 9 and 15 ketones in aqueous solution followed by subsequent extraction, methylation and t-butyldimethyl silylation of the free hydroxyl groups at 11 and on the oximes. Deuterogenated 13,14-dihydro-15-keto-PGE2 is used as the internal standard and can be stored as the oxime and added with the oximating solution immediately the biological sample is obtained. The sensitivity of the method allows measurement of 2 ng of 13,14-dihydro-15keto-PGE2 in tissue incubates. The intra-batch precision is 11.8% and the inter-batch precision for measurement of 100 ng of metabolite is 8.1%.

摘要

前列腺素E2(PGE2)的主要代谢产物13,14-二氢-15-酮-PGE2很容易脱水,并随后可形成环状衍生物。这个问题可以通过在水溶液中立即形成9-酮和15-酮的肟,随后对11位的游离羟基以及肟进行萃取、甲基化和叔丁基二甲基硅烷化来克服。氘代的13,14-二氢-15-酮-PGE2用作内标,可作为肟储存,并在获得生物样品后立即与肟化溶液一起添加。该方法的灵敏度允许在组织培养液中测量2 ng的13,14-二氢-15-酮-PGE2。批内精密度为11.8%,测量100 ng代谢产物的批间精密度为8.1%。